How Many lights and outlets on a 15amp circuit

The closest guideline to how many outlets can you put on 15 A circuits is found in the NEC 210.21 Chapter titled ‘Outlet devices. This NEC chapter includes a table that specifies circuit ratings, acceptable ratings, and maximum load such a circuit can handle.



What does the Outlet Devices Requirement Mean?


The outlet devices covered in this Chapter of the NEC include receptacles, switches, and receptacle outlets. These outlet devices are discussed in terms of maximum amperage, maximum conductor size, and maximum number of conductors. When installing a circuit, you should select a breaker that is rated at least 10% greater than the load amperage. You should select the wire size that is rated at least 10% greater than the breaker size. Lastly, you should select the number of outlets that is rated at least 10% less than the breaker size. Maximum 
amperage, maximum conductor size, and maximum number of conductors at a device location are the basis of these three requirements.


Ampacity (AC)
The ampacity of a wire is the maximum current it can carry safely. The current capacity of the wire depends on the type of wire and the conditions in which it is installed. The NEC provides tables of ampacity for many common wire types. The ampacity of a wire must be at least 10% higher than the expected current, in order to account for voltage drop due to the resistance of the wire. When you use the tables in the NEC to determine the ampacity of conductors, you must use the rating of the conductor in its “Worst Conditions” rating. The worst conditions are a 90degree temperature rise and a 2% voltage drop. So if you use 12 gauge wire and 90 degree rise, you must use the 10 amp rating of the 12 gauge wire.

Maximum Conductor Size
The maximum conductor size for a circuit is also found in the NEC tables. This is the maximum allowable wire size for a circuit based on the expected current. The wire size for a circuit must be at least 10% greater than the expected current. The maximum conductor size for a circuit is based on the amperage and voltage of the circuit. The maximum conductor size is found in the tables by first finding the circuit voltage, then going to the table and finding the amperage at that voltage. For example, if the voltage of a circuit is 110 volts, and the circuit current is 10 amps, the maximum wire size allowed is No. 10. This is based on the fact that the maximum current is 10 amps and 110 volts is 110/120 volts, which is less than the allowed voltage of 120 volts.

Maximum Number of Conductors at a Device Location and Cable Lengths

The maximum number of conductors allowed at a device location is based on the circuit breaker rating and the type of wiring in the circuit. Conductors are the wires that carry current from the source to the device. For example, a circuit with a 15amp breaker can have a maximum of two 12/2 (12gauge, 2 conductor) and two 12/3 (12gauge, 3 conductor) ungrounded cables. The maximum length of cables at a device location is also found in the tables. The NEC lists three tables for determining maximum cable length for different types of conditions. The type of cable and type of installation will decide which table to reference.

15 Amp Breaker Limits on Wire Size and Number of Outlets


A 15amp circuit can be wired with 12/3 UF or 12/3 SE cable. The circuit can have a maximum of two 12/3 UF or 12/3 SE ungrounded cables, two 15amp outlets, or two 15 amp switched outlets. In this type of circuit, the wire size is 12 gauge. A 15amp circuit can be wired with 12/2 UF or 12/2 SE cable. The circuit can have a maximum of two 12/2 UF or 12/2 SE ungrounded cables, two 15amp outlets, or two 15 amp switched outlets. In this type of circuit, the wire size is 10 gauge. A 15amp circuit can be wired with 12/2 UF or 12/2 SE cable. The circuit can have a maximum of two 12/2 UF or 12/2 SE ungrounded cables, one 20amp outlet, or one 20 amp switched outlet. In this type of circuit, the wire size is 10 gauge.

How many lights on a 15amp circuit-

Domestic electrical circuits are intentionally designed to use specific electrical loads within a certain margin of safety. If you plan to add new lighting fixtures to your home, you should ensure that the circuits are not overloaded. So how do you calculate how many lights can run on a 15amp circuit?

The number of lamps that can run on a 15amp circuit depends on the wattage of the lamp. The total current consumed by the circuit light should not exceed 80% of the circuit breaker rating. For a 15amp circuit breaker, this is a maximum of 12 amps. You can start with a 60watt light and connect up to 24 lights to a 15amp circuit breaker.


Low Watt LED Lamps, If you are using 10 Watt LED lamps, you can install up to 150 lamps in one circuit. We do not recommend using non-LED bulbs because you cannot exceed 15 amps without tripping the circuit. However this is a good example of why LED bulbs are better at saving energy. Proper loading of circuits is a matter of home safety. Overloading your circuits is not only frustrating, but it poses a fire risk to your home. Let's see how to accurately determine the capacity of a 15amp circuit.


 